Resource Constraints
Instruction Set3-24 SPRU733
3.7.6 Constraints on Register Reads
More than four reads of the same register cannot occur on the same cycle.
Conditional registers are not included in this count.
The following execute packets are invalid:
MPY .M1 A1, A1, A4 ; five reads of register A1
|| ADD .L1 A1, A1, A5
|| SUB .D1 A1, A2, A3
MPY .M1 A1, A1, A4 ; five reads of register A1
|| ADD .L1 A1, A1, A5
|| SUB .D2x A1, B2, B3
The following execute packet is valid:
MPY .M1 A1, A1, A4 ; only four reads of A1
|| [A1] ADD .L1 A0, A1, A5
|| SUB .D1 A1, A2, A3
Seitenansicht 83