www.ti.com
PRODUCT PREVIEW
TMS320C6454
Fixed-Point Digital Signal Processor
SPRS311A APRIL 2006 REVISED DECEMBER 2006
7.7.3.10 SYSCLK Status Register
The SYSCLK status register (SYSTAT) shows the status of the system clocks (SYSCLK n). SYSTAT is
shown in Figure 7-20 and described in Table 7-28 .
31 16
Reserved
R-0
15 8
Reserved
R-0
7 5 4 3 2 1 0
Reserved SYS5ON SYS4ON SYS3ON SYS2ON Reserved
R-0 R-1 R-1 R-1 R-1 R-1
LEGEND: R = Read only; - n = value after reset
Figure 7-20. SYSCLK Status Register (SYSTAT) [Hex Address: 029A 0150]
Table 7-28. SYSCLK Status Register (SYSTAT) Field Descriptions
Bit Field Value Description
31:4 Reserved 0 Reserved. The reserved bit location is always read as 0. A value written to this field has no effect.
4:1 SYS nON SYSCLK n on status.
0 SYSCLK n is gated.
1 SYSCLK n is on.
0 Reserved 1 Reserved. The reserved bit location is always read as 1. A value written to this field has no effect.